Transmitter Circuit Configuration Standby Control Timing AT Unit Digital Control Unit Option Setting Extended Function Adjustment Function NB X The r universal transmitter sends a signal to alarm panel when the associated magnet moves away from the case, and sends a restore signal when the magnet is re-aligned.

If required, you can wire external normally closed devices e. Up to 4 remote keypads can be connected to the control panel. Each remote keypad has two hard wired detection circuits and a single switched -ve output. There are two types of remote keypads that can be used:. The Remote Arming Station only allows setting and unsetting of the system.

Strobe output. Outputs 1- 3. With a wirefree system we recommend that you carry out radio tests as part of a site survey to ensure that the control panel can receive the radio signal from the detectors. If you cannot do the tests during a survey, carry them out before installation.

Place the control panel in its planned location. Power up the control panel. Program the control panel to learn a detector. Select the "Walk Test" option see user guide. Test the reception by triggering the detector at each planned location. If the control panel generates a tone the detector is being received. Switch the test transmitter on and place it at the proposed site for the control panel.

The transmitter sends a pulsed signal, 10 seconds on and 5 seconds off. Switch the test meter into "Track" mode and walk around the premises.

Check that the signal strength is between 5 and 9 at each proposed location for detectors. Move to a different location to improve the signal strength if it is between 1 and 4. Make sure the new location is suitable for the detector. Change the location of the test transmitter if the signal strength is not greater than 4 for any transmitter, make sure that the user agrees to the new location for the control panel. For certified systems note down the signal strength for each detector location and keep a record in the control panel and in the installation file.

Positioned in a convenient location to connect the mains supply. Positioned within the protected area. Positioned in a convenient location so that the users can reach the control panel in order to operate the system.

Ensure that there is a clear space around the control panel to allow it to receive a good radio signal. Outside the area covered by the alarm system. Close to or on large metal structures, for example: water tanks, cars, fridges and freezers. Closer than 1 metre to mains wiring and metal water or gas pipes. Next to high voltage electrical equipment, or electronic equipment, particularly computers, photocopiers or other radios.

Ensure that all Network and hard wired detection circuit cables are kept clear of mains supply cables, telephone cables, R.

Mains power supply cables to the system must be connected to an un-switched fused spur that cannot be accidentally switched off. The mains cable must enter the housing via its own cable entry point. The main supply cable for the TSR must enter the control panel via this entry point. Radio receving aerial. The aerial must positioned as shown when refitting the PCB. The mains transformer which transforms the incoming mains supply down to 18V a.

The mains connection terminals for the TSR. The terminal block is fitted with a mA fuse. Remove the screw from the top of the control panel and lift away the front cover. Hold the control panel back box in the required position keyhole to the top and mark the centre of the keyhole position. Remove the back box, drill and plug the hole. Page Program Circuits [1. Each circuit must be programmed in are omitted. Page System Timers [1. If the timer is set to the bell for the duration of the "Pset Bel.

Page Setting Modes [1. Page Configuration [1. Page Goto User Menu 1 [1. This option allows the engineer to re-map the remote keypad circuits. By default all wirefree 3. Press [C] to remove an existing device. Page View Circuits [2. The circuit status conditions remote keypads and is also used to time stamp and resistance are shown below: events in the system event log. Page Change Passcode [2. The default passcode is but the connected to the system it is possible to print a installation engineer should change this to their selected number of events.

Press [A] for earlier events, [C] for later events, [B] to display time of event, then [B] again for date of event 6. Press [ESC] Display shows 2- 7. Press [ESC] Display shows 1- 8.

Press [2] Display shows 5. Enter [time in 24 hour format] Display shows new time 6. Press [ENT] Display shows 2- 7. Press [3] Display shows 8. Enter [ddmm] Display shows new date no years 9. Press [ENT] Display shows 2- Back to Index. Full set the system. Part set the system. Unset the system.